MobilHybrid does not charge when the generator is connected

Check the following:

  1. MobilHybrid is switched off? Solution: Switch on the device.
  2. Emergency stop is activated? Solution: Release the emergency stop.
  3. Batteries are full? Solution: No action necessary.
  4. Input fuse generator on MobilHybrid dropped? Solution: Search for the error, eliminate it and restart.
  5. Insulation monitor has detected insulation fault? Solution: Search for the error, eliminate it and restart.
  6. Wrong rotating field of the supply line? Solution: Have it checked by a qualified electrician and changed to clockwise rotation. If the supply line is connected with clockwise rotating field, a clearly audible switching/clacking of the contactor can be heard when the supply cable is plugged in and unplugged at the "Generator/Grid" input of the MobilHybrid.